Controller Location Selection
The SubDrive controller is intended for operation in ambient temperatures
up to 125°F (51°C) at 230 VAC input. The following recommendations will
help in selection of the proper location of the SubDrive unit:
up to 125°F (51°C) at 230 VAC input. The following recommendations will
help in selection of the proper location of the SubDrive unit:
1. A tank tee is recommended for mounting the tank, pressure sensor,
pressure gauge, and pressure relief valve at one junction. If a tank
tee is not used, the pressure sensor should be located within 6 feet
(1.8 meters) of the pressure tank to minimize pressure fl uctuations.
There should be no elbows between the tank and pressure sensor.
tee is not used, the pressure sensor should be located within 6 feet
(1.8 meters) of the pressure tank to minimize pressure fl uctuations.
There should be no elbows between the tank and pressure sensor.
2. The unit should be mounted on a sturdy supporting structure such as a
wall or supporting post. Please take into account the weight of the unit,
which weighs approximately 34 pounds (15.5 kg).
which weighs approximately 34 pounds (15.5 kg).
3. The electronics inside the SubDrive are air-cooled. As a result, there
should be at least 6 inches of clearance above and below the unit to
allow room for air fl ow.
allow room for air fl ow.
* NOTE: there should be no elbows between the tank and pressure sensor.
▲
CAUTION
!
There should be at least 6 inches of clearance above and below the
unit to allow room for air fl ow.
unit to allow room for air fl ow.
Pressure
Sensor
Pressure
Relief Valve
Pressure
Tank
6"
min.
6"
min.
Clearance
For
Air Flow
6 Feet or Less
(Pressure Tank to PressureSensor)
*
Pressure
Shut-off
Sensor
PUMP
MOTOR