Controller Location Selection
The SubDrive controller is intended for operation in ambient temperatures 
up to 125°F (51°C) at 230 VAC input. The following recommendations will 
help in selection of the proper location of the SubDrive unit:
1.  A tank tee is recommended for mounting the tank, pressure sensor, 
pressure gauge, and pressure relief valve at one junction. If a tank 
tee is not used, the pressure sensor should be located within 6 feet 
(1.8 meters) of the pressure tank to minimize pressure fl uctuations. 
There should be no elbows between the tank and pressure sensor.
2.  The unit should be mounted on a sturdy supporting structure such as a 
wall or supporting post. Please take into account the weight of the unit, 
which weighs approximately 34 pounds (15.5 kg).
3.  The electronics inside the SubDrive are air-cooled. As a result, there 
should be at least 6 inches of clearance above and below the unit to 
allow room for air fl ow.
* NOTE: there should be no elbows between the tank and pressure sensor.
 CAUTION
!
There should be at least 6 inches of clearance above and below the 
unit to allow room for air fl ow.
Pressure
Sensor
Pressure
Relief Valve
Pressure
Tank
6"
min.
6"
min.
Clearance
For
Air Flow
6 Feet or Less
(Pressure Tank to PressureSensor)
*
Pressure
Shut-off
Sensor
PUMP