PRIOR TO COUPLING DRIVER TO PUMP, ROTATION OF 
DRIVER SHOULD BE CHECKED! Serious damage can result 
if  pump  is  rotated  in  wrong  direction.  Once  motor  rotation 
is  checked,  connect  coupling,  following  the  manufacturer’s 
instructions.  If  a  coupling  guard  is  furnished  with  the  unit, 
ensure that it is securely fastened in place.
II-F. Stufng Box
1. Packing: 
If the pumpage is dirty or hot, it is not suitable to lubricate the 
packing. An external source must be utilized, unless the bypass 
is equipped with proper separator, filter, and/or cooling system. 
This must be piped into the lantern ring connection, also (refer 
to packing recommendations).
2. Mechanical Seals: 
When  mechanical  seals  are  supplied,  they  are  installed  and 
adjusted at the factory. They must not run dry or in abrasives. 
Connect recirculation, flush and/or cooling lines as required, 
following instructions on the seal print supplied for the unit.
III-A. Startup
1. Check List
a.   Lubrication—Pump bearings are normally oil lubricated. 
(THE BEARINGS ARE NOT LUBRICATED AT THE 
FACTORY.) These pumps are supplied with an oiler which 
maintains a constant oil level in the bearing frame. Locate 
oiler  as  shown  on  the  outline  drawings  supplied  for  the 
unit. See Fig. 6 for correct adjustment of oiler.
SECTION III—OPERATION
Figure 3
Figure 5
Figure 6
Figure 4
R O TAT E 
THIS HUB
Figure 4
OIL LEVEL
OIL LEVEL
SET SCREW
WEDGES