Roland Fantom-X8 Manual Do Utilizador

Página de 348
 
190
Editing Songs
 
Bias
 
Specify the amount (number of ticks) by which the sequencer data 
will be moved.
 
Value:
 
 -4800– +4800
 
Status
 
Selects the type of data to be shifted in time.
 
Value
ALL
NOTE
Polyphonic Aftertouch
Control Change
Program Change
Channel Aftertouch
Pitch Bend
System Exclusive
Tune Request
Pattern Call
 
If the Track parameter is set to “TEMPO,” the Status parameter 
will not be available.
 
Range Min, Range Max
 
If you set the Status parameter to “NOTE,” “P.AFT,” “C.C,” or 
“PROG,” specify the range of data. Set “Range Min” to the lowest 
value of the range, and “Range Max” to the highest value of the 
range.
 
To shift all notes or polyphonic aftertouch data, set “Range 
Min” to “C -1” and “Range Max” to “G9.” To shift C4, set 
“Range Min” and “Range Max” to “C4.” To shift C3 through 
C4, set “Range Min” to “C3” and “Range Max” to “C4.”
• To shift all controller numbers, set “Range Min” to “0” and 
“Range Max” to “127.” To shift all program numbers, set 
“Range Min” to “1” and “Range Max” to “128.” To shift number 
4, set “Range Min” and “Range Max” to “4.” To shift numbers 3 
through 14, set “Range Min” to “3” and “Range Max” to “14.”
Continuously variable controllers such as aftertouch, pitch bend, and 
expression tend to create unexpectedly large amounts of data when 
operated. Data Thin will strip out redundant data to increase the 
amount of memory available for the sequencer.
 
fig.19-022_50
 
 
 
 
Track / Pattern (Source Track)
 
Specifies the track(s) or pattern whose sequencer data will be 
thinned.
 
Value
ALL:
 
Phrase tracks 1–16, the beat track, and the tempo 
track
 
TRK 1–TRK 16:
 
The specified phrase track
 
PTN001–PTN100:
 
The specified pattern
 
Ch / Part
 
Selects MIDI channel of the data to be thinned.
To thin all sequencer data, set this parameter to ALL. To thin 
sequencer data of just one specific MIDI channel, select that MIDI 
channel.
 
Value:
 
 ALL, Ch1–Ch16
 
Measure, For (Edit Range)
 
Specifies the range of measures whose sequencer data will be 
thinned. If you set “For” to “ALL,” all measures will be specified.
 
Data Thin Value
 
For thinning data which incorporates rapid changes, use higher 
settings. If you don’t want to thin that much data even though it is 
subject to rapid change, use lower settings.
 
Data Thin Time
 
If you are thinning data that changes gradually over time, use higher 
settings. If you don’t want to thin that much data even though the 
changes are gradual, use lower settings.
 
Thinning Out the Sequencer Data 
(Data Thin)
Fantom-X678_r_e.book 190 ページ 2005年5月12日 木曜日 午後4時40分