TROUBLESHOOTING GUIDE
TT
RR
OO
UU
BB
LLEE
SS
HH
OO
OO
TT
IINN
GG
  GG
UU
IIDD
EE
FILTER MOTOR 
FAILS TO START
FILTER DOESN’T
CLEAN POOL
FILTER DOESN’T
PUMP WATER OR
FLOW IS VERY
SLOW
PUMP DOESN’T
WORK
TOP COVER 
LEAKING
HOSE LEAKING
AIR LOCK
• Not plugged in.
• Fuse box needs checking.
• GFCI/RCD circuit breaker 
tripped.
• Improper chlorine or pH 
levels.
• Filter cartridge dirty.
• Cartridge damaged.
• Excessively dirty pool.
• Strainer screen restricting 
flow.
• Inlet/discharge clogged.
• Air leak on intake line.
• Scale or buildup on cartridge.
• Excessively dirty pool.
• Filter cartridge dirty.
• Low water level.
• Strainer screen plugged up.
• Air leak on intake hose.
• Faulty motor or impeller 
jammed.
• Air lock inside cartridge 
chamber.
• O-ring missing.
• Cover not tight.
• Filter cartridge dirty.
• Hose nuts.
• Pump housing and inlet hose 
air trapped.
•  Inlet and outlet hoses 
connection reversed.
TROUBLE                          CHECK                            POSSIBLE SOLUTIONS
IMPORTANT
If you continue to experience difficulty, please contact our
Consumer Service Department for assistance. See back cover for
contact information.
• Filter cord must be plugged into a 3 wire 
outlet that is protected by a Class A 
Ground Fault Circuit Interrupter, or RCD.
• Reset circuit breaker. If circuit breaker
trips repeatedly, your electrical system 
may have a defect. Turn off circuit 
breaker and call an electrician to 
correct the problem.
• Motor too hot and overload protection 
shut motor off. Let motor cool down.
• Adjust chlorine and pH level. Consult 
your local swimming pool supply stores.
• Clean or replace cartridge.
• Check for holes in cartridge. Replace 
if damaged.
• Operate filter for longer periods.
• Clean strainer screen at pool wall inlet.
• Look for obstructions in intake hose or 
discharge hose inside pool wall.
• Tighten hose nuts, check hoses for
damage, check pool water level.
• Replace cartridge.
• Clean cartridge more often.
• Clean inside plunger valve.
• Pull valve handle to full upright position.
• Fill pool to correct water level.
• Clean strainer screens at pool inlet.
• Tighten hose nuts, check hose for damage.
• Check & clear any sticks or leaves in 
intake to pump.
• Turn & pull valve handle to full upright 
position.
• Remove cover & check for O-ring.
• Tighten cover (Manually).
• Replace or clean cartridge.
• Tighten/reinstall hose nut.
• Open air release valves, wait until water 
starts to flow out of the air release 
valves, close air release valves.
• Lower position of pool outlet connect 
to filter pump water inlet, upper 
position of pool inlet connect to filter 
pump water outlet.