Wet End Removal, Inspection, & Reinstallation 
 
 
I
F THE DIAPHRAGM HAS FAILED
,
 PROCESS FLUID MAY HAVE CONTAMINATED THE PUMP 
ECCENTRIC HOUSING 
(
ALTHOUGH NORMALLY
,
 ANY PROCESS FLUID BEHIND A FAILED 
DIAPHRAGM WOULD PASS THROUGH THE BOTTOM DRAIN HOLE
).
  
H
ANDLE WITH APPROPRIATE 
CARE
 
 
Figure 8, wet end components 
 
OMNI
®
 diaphragms do not have a specific cycle life; however, the accumulation of foreign material 
or debris sufficient to deform the diaphragm can eventually cause failure.  Failure can also occur as a 
result of system over pressure or chemical attack.  Periodic diaphragm inspection and replacement are 
recommended.  Each user should perform regular inspections to determine the replacement interval 
that is appropriate to their system conditions.