To remove the 92mm fan assembly, do the following:
1. Power-off the server, if it is on.
2. Unplug the server.
3. Remove the left-side cover (see “Removing the side 
4. Turn the server onto its right side so that the open left 
side is facing up.
Note: Rotate the feet in toward the server so they do 
not detach due to the weight of the server.
5. Remove the support bracket (see “Removing the sup-
6. Remove all adapter cards (see “Working with adapters” 
7. Detach cables from the system board.
8. Remove the card guide (see “Adapter card guide” on 
9. Remove the fan from the assembly:
a. Gently pull the fan assembly away from the card 
guide.
b. Pull the rubber extensions through the apertures.
10. Install the new fan in the assembly:
a. Align the rubber extensions in the fan assembly 
with the apertures in the card guide and gently 
press the fan into place.
b. Use needle-nosed pliers to pull the rubber exten-
sions through the apertures.
11. Replace the assembly in the server:
a. Insert the two tabs on the bottom of the card guide 
into the slots on the server.