IBM 21Y Manual Do Utilizador
Symptom-to-FRU index
135
035-XXX-S99
(Failed RAID test
on PCI slot S. S =
number of failing
PCI slot. Check
System Error Log
before replacing a
FRU.)
(Failed RAID test
on PCI slot S. S =
number of failing
PCI slot. Check
System Error Log
before replacing a
FRU.)
1. Adapter
2. SCSI Backplane
3. Cable
035-XXX-SNN
(Check System
Error Log before
replacing a FRU.
S = number of
failing PCI slot; NN
= SCSI ID of failing
fixed disk.)
(Check System
Error Log before
replacing a FRU.
S = number of
failing PCI slot; NN
= SCSI ID of failing
fixed disk.)
1. Fixed Disk with SCSI ID NN
on RAID adapter in PCI slot
S.
S.
035-253-S99
(RAID adapter
initialization failure)
(RAID adapter
initialization failure)
1. ServeRAID Adapter in slot S
is not configured properly.
Obtain the basic and extended
configuration status and refer
to the ServeRAID Hardware
Maintenance Manual for more
information.
Obtain the basic and extended
configuration status and refer
to the ServeRAID Hardware
Maintenance Manual for more
information.
2. Cable
3. Adapter
075-XXX-000
(Failed Power
Supply test)
(Failed Power
Supply test)
1. Power Supply
089-XXX-001
(Failed
Microprocessor
test)
(Failed
Microprocessor
test)
1. Microprocessor
089-XXX-002
(Failed Optional
Microprocessor
test)
(Failed Optional
Microprocessor
test)
1. Optional Microprocessor 2
180-XXX-003
(Failed System
Board LED test)
(Failed System
Board LED test)
1. System Board
1. DIMM Location J1-J4
2. Memory card
201-XXX-999
(Multiple DIMM
failure, see error
text.)
(Multiple DIMM
failure, see error
text.)
1. See error text for failing
DIMMs
2. Memory card
Error