IBM 21Y Manual Do Utilizador

Página de 210
 Symptom-to-FRU index
 
135
035-XXX-S99            
(Failed RAID test 
on PCI slot S.  S = 
number of failing 
PCI slot.  Check 
System Error Log 
before replacing a 
FRU.)
1. Adapter
2. SCSI Backplane
3. Cable
035-XXX-SNN       
(Check System 
Error Log before 
replacing a FRU.      
S = number of 
failing PCI slot; NN 
= SCSI ID of failing 
fixed disk.)
1. Fixed Disk with SCSI ID NN 
on RAID adapter in PCI slot 
S.
035-253-S99           
(RAID adapter 
initialization failure)
1. ServeRAID Adapter in slot S 
is not configured properly. 
Obtain the basic and extended 
configuration status and refer 
to the ServeRAID Hardware 
Maintenance Manual for more 
information.
2. Cable
3. Adapter
075-XXX-000        
(Failed Power 
Supply test)
1. Power Supply
089-XXX-001          
(Failed 
Microprocessor 
test)
1. Microprocessor
089-XXX-002                                   
(Failed Optional 
Microprocessor 
test)
1. Optional Microprocessor 2
180-XXX-003        
(Failed System 
Board LED test)
1. System Board
201-XXX-0NN                
(Failed Memory 
test, see "Memory 
Settings" on page 
36.)  NN = DIMM 
location.
1. DIMM Location J1-J4
2. Memory card
201-XXX-999   
(Multiple DIMM 
failure, see error 
text.)
1. See error text for failing 
DIMMs
2. Memory card
Error 
Code/Symptom
FRU/Action