IBM 21Y Manual Do Utilizador

Página de 210
 Symptom-to-FRU index
 
137
217-XXX-003        
(Failed BIOS Fixed 
Disk test)  
Note: If RAID is 
configured, 
the fixed 
disk number 
refers to the 
RAID logical 
array.
1. Fixed Disk 4
217-XXX-004        
(Failed BIOS Fixed 
Disk test)  
Note: If RAID is 
configured, 
the fixed 
disk number 
refers to the 
RAID logical 
array.
1. Fixed Disk 5
217-XXX-005        
(Failed BIOS Fixed 
Disk test)  
Note: If RAID is 
configured, 
the fixed 
disk number 
refers to the 
RAID logical 
array.
1. Fixed Disk 6
264-XXX-0NN                    
(NN = SCSI ID of 
failing Tape Drive)
1. Tape Cartridge, if user 
executed the Read/Write 
Tape Drive test (XXX = 256)
2. SCSI or power cable 
connected to the tape drive 
with SCSI ID NN
3. Tape drive with SCSI ID NN – 
refer to Help and Service 
Information appendix of tape 
drive’s User Guide.
4. I/O Legacy Board or SCSI 
Controller – run SCSI 
Controller diagnostic to 
determine of SCSI bus is 
functioning properly.
264-XXX-999             
(Errors on multiple 
tape drives, see 
error text for more 
info)
1. See error messages/text in 
the PC Doctor error log for 
detailed information on each 
individual tape drive error.
Error 
Code/Symptom
FRU/Action