IBM 21Y Manual Do Utilizador

Página de 210
 Symptom-to-FRU index
 
139
CD-ROM drive 
cable is not 
plugged in.
1. Make sure CD-ROM drive 
cable is plugged in.
Diskette drive in-
use light stays on, 
or the system 
bypasses the 
diskette drive, or 
the diskette drive 
does not work.
1. If there is a diskette in the 
drive, verify that: 
a. The diskette drive is 
enabled in the 
Configuration/Setup 
utility program.
b. The diskette is good 
and not damaged.   (Try 
another diskette if you 
have one.)
c. The diskette is inserted 
correctly in the drive.
d. The diskette contains 
the necessary files to 
start the server.
e. The software program is 
OK.
f. Cable is installed 
correctly (proper 
orientation)
2. Run Diskette Drive 
Diagnostics.
3. Cable
4. Diskette Drive
5. System Board
Monitor problems 
(general).  
Some 
IBM monitors have 
their own self-tests.  
If you suspect a 
problem with the 
monitor, refer to the 
information that 
comes with the 
monitor for adjusting 
and testing 
instructions.
1. Monitor
2. Run Video Diagnostics.  If 
diagnostics pass, the 
problem may be a video 
driver.
3. Display Adapter / System 
Board
General
FRU/Action