IBM 21Y Manual Do Utilizador

Página de 210
142
Netfinity 3500-M20 – Type 8657 Models 21Y, 22Y, 31Y, 32Y,
101, 102, 106                     
(System and 
microprocessor 
error)
1. System Board
111 
(Channel check 
error)
1. Failing adapter
2. DIMM
3. System board
114
(Adapter read-only 
memory error)
1. Failing adapter
2. Run diagnostics
129 
(Internal cache 
error)
1. Microprocessor
2. Optional microprocessor (if 
installed)
151            
(Real time clock 
error)
1. Run Diagnostics
2. Battery
3. System Board
161             
(Real time clock 
battery error)
1. Run Configuration/Setup
2. Battery
3. System Board
162          
(Device 
Configuration Error)  
Note: Be sure to 
load the 
default 
settings and 
any 
additional 
desired 
settings; 
then, save 
the 
configura-
tion.
1. Run Configuration/Setup
2. Battery
3. Failing Device
4. System Board
163               
(Real-Time Clock 
error)
1. Run Configuration/Setup
2. Battery
3. System Board
164     
(Memory 
configuration 
changed, see 
"Memory Settings" 
on page 36.)
1. Run Configuration/Setup
2. DIMM
3. Memory Card
4. System Board
175       
(Hardware error)
1. System Board
Error 
Code/Symptom
FRU/Action