IBM 21Y Manual Do Utilizador

Página de 210
 Symptom-to-FRU index
 
143
176, 177, 178            
(Security hardware 
error)
1. Run Configuration/Setup
2. System Board
184        
(Power-on 
password 
corrupted)
1. Run Configuration/Setup
2. System Board
185           
(Drive startup 
sequence 
information 
corrupted)
1. Run Configuration/Setup
2. System Board
186         
(Security hardware 
control logic failed)
1. Run Configuration/Setup
2. System Board
187             
(VPD serial number 
not set.)
1. Set serial number in Setup
2. System Board
188              
(Bad EEPROM 
CRC #2)
1. Run Configuration/Setup
2. System Board
189                
(Three attempts 
were made to 
access the server 
with invalid 
passwords)
1. Run Configuration/Setup, 
enter the administrator 
password
2. System Board.
201     
(Memory test error, 
see "Memory 
Settings" on page 
36.)  If the server 
does not have the 
latest level of BIOS 
installed, update 
the BIOS to the 
latest level and run 
the diagnostic 
program again.
1. Run memory diagnostics.
2. DIMM
3. System Board
229          
(Cache error)
1. Microprocessor
2. Optional microprocessor  (if 
installed)
289        
(DIMM has been 
disabled by user or 
system, see 
"Memory Settings" 
on page 36.)
1. Run Configuration/Setup, if 
disabled by user
2. Disabled DIMM, if not disabled 
by user.
Error 
Code/Symptom
FRU/Action