IBM 21Y Manual Do Utilizador

Página de 210
 Installing options
 
51
Bay C is for a 3.5-inch slim-high removable-media drive 
or a SCSI hard disk drive.
Note: The electromagnetic interference (EMI) integrity and 
cooling of the server are both protected by having 
bays A through D covered or occupied.  When you 
install a drive, save the filler panel from the bay, in 
case you later remove the drive and do not replace it 
with another.
Preinstallation steps (all bays)
Before you install drives in the server, verify that you have all 
the cables and any other equipment specified in the docu-
mentation that comes with the  drive. You might also need to 
perform certain preinstallation activities. Some of the steps 
are required only during the initial installation of an option.
trostatic discharge-sensitive devices” on page 158, and 
the documentation that comes with the drive.
2. Choose the bay in which you want to install the drive.
3. Check the instructions that come with the drive to see if 
you need to set any switches or jumpers on the drive.  
Be sure to set the SCSI ID on a SCSI device.
Installing a drive in bays A, B, C, or D
Note: The EMI integrity and cooling of the server are both 
protected by having the bays covered or occupied.  
When you install a drive, save the filler panel from the 
bay, in case you later remove the drive and do not 
replace it with another.
M 2
0
Ne
tfini
ty 3
500