DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1692
TBRI-PT (TN2185 ISDN Trunk-Side BRI Port) 
9
When the TN2185 circuit pack detects a slip condition, maintenance software 
initiates the Slip Alarm Inquiry Test to query the slip counters on the TN2185 
circuit pack and total the slip counts in the maintenance software. 
If the slip count is over the threshold, a Minor alarm is raised against the TN2185 
circuit pack, leaving all ports of the TN2185 circuit pack in the in-service state. If 
the TN2185 circuit pack is used to supply the system synchronization source, the 
MINOR alarm will initiate a synchronization source switch. See TDM-BUS and 
SYNC for additional information.
Table I-4.
TEST #1244 Slip Alarm Inquiry Test 
Error 
Code
Test Result
Description/ Recommendation
 
ABORT
Internal System Error
2000
ABORT
Response to the test request was not received within the allowable time 
period. If Error Type 1538 is present in the Error Log, follow the 
maintenance strategy recommended for this error type.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1 to 88
FAIL
The circuit pack and the remote endpoint are not synchronized to the 
same clock rate, which has generated the Slip alarm. The error code 
equals the number of slips detected by the TN2185 circuit pack since 
the last Slip Alarm Inquiry Test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the circuit pack is a TN2185, enter the list measurement ds1-log 
UUCSS command to read the error seconds measurement.
3. Verify that both endpoints of the DS1 link are administered using the 
same signaling mode, framing mode, and line coding.
4. Check the physical connections of DS1 Interface circuit packs and 
cable.
5. Replace the local DS1 Interface circuit pack and repeat the test.
6. Contact T1 Network Service to diagnose the remote DS1 endpoint.
 
PASS
No Slip alarm is detected on the DS1 Interface circuit pack.
0
NO BOARD
The DS1 Interface circuit pack is not administered.
1. Administer the DS1 Interface circuit pack by issuing the add ds1 
UUCSS command.
2. Run the test again.
3. If the test continues to return NO BOARD, escalate the problem.