Lucent Technologies Release 7 Manual Do Utilizador

Página de 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1693
TBRI-TRK (TN2185 ISDN Trunk-Side BRI) 
9
TBRI-TRK (TN2185 
ISDN Trunk-Side BRI)
The TN2185 circuit pack contains eight, 4-wire ports that interface to the network 
at the ISDN S/T reference point over two 64 Kb/s channels (B1 and B2) and over 
a 16Kb/s signaling (D) channel. The B1 and B2 channels can be simultaneously 
circuit switched, or individually packet switched. Only one channel per trunk can 
be packet switched due to Packet Processing Element (PPE) limitations. The D 
channel is either circuit switched or packet switched. Packet switching uses the 
PPE to combine all D channels into a single physical channel, which is then 
routed via the concentration highway to the Network Control Element (NCE) and 
then to the TDM bus. The circuit-switched connections have a Mu-law or A-law 
option for voice and operate as 64Kb/s clear data channels. The 
packet-switched channels support the LAPD protocol and conform with the 
CCITT Q.920 Recommendations for D-channel signaling. 
LEDs
The three LEDs on the circuit pack’s faceplate indicate board status. When 
illuminated, the red LED indicates a board failure or a major or minor on-board 
alarm, the green LED indicates that testing is in progress, and the amber LED 
indicates that the board is in use.
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to Run
1
1.
Where UU is the universal cabinet number (1 for PPN, 2 -44 for EPN), C is the carrier designation 
(A, B, C, D, or E), SS is the carrier slot address where the circuit pack is located (1, 2, and so 
forth), and pp is the two-digit port number (1, 2, 3, and so forth).
Full Name of MO
TBRI-TRK
2
2.
For additional repair information, also see TBRI-BD and TBRI-PT Maintenance documentation.
MAJOR
3
3.
A MAJOR alarm on a trunk indicates that alarms on these trunks are not downgraded by the set 
options
 command and that at least 75 percent of the trunks in this trunk group are alarmed.
test trunk UUCSSpp l
MO_TBRI_TRK
TBRI-TRK
MINOR
test trunk UUCSSpp l
MO_TBRI_TRK
TBRI-TRK
WARNING
test trunk UUCSSpp sh
MO_TBRI_TRK