Philips 320 Manual Do Utilizador

Página de 24
2005-12-12
 
 
Page 19 
6 TROUBLE 
SHOOTING 
This chapter describes the action to take if the Inca camera 
does not operate correctly or how to receive support. 
6.1 
KNOWN PROBLEMS USING THE INCA 
When using the Micro D to Sub D cable (8122 410 81530) 
that is also included into the starter kit please notice that 
the point 5 and 7 are interchanged all other points are 
interconnected one to one. 
 
The cleanness of the sensor is of major importance for the 
image quality. During the production of the Inca special 
account is taken with respect to the cleanness of the 
sensor. However when you remove the sensor protection 
cap from the Inca front end prior to the mounting of the 
lens, the sensor can attract some dust or dirt. This pollution 
can affect the image captured with the Inca. Remove the 
sensor protection cap only in a clean environment by 
holding the Inca with the sensor facing down. After 
removing the sensor protection cap inspect the cleanness 
of the sensor and immediate assemble the required lens to 
the Inca. 
 
In case of a red blinking system LED (see 2.4.2 System 
LED) du
ring booting one of the following files are probably 
missing on the flash file system; ‘RapIB320Lcm.rbf’ or the 
appropriate license file Rhapsody.key or Clicks.key. These 
files are required when you like to use the Inca either 
under Rhapsody or Clicks software control.