EarthQuake 9010140 Manual Do Utilizador

Página de 44
Page 14
GetEarthquake.com
1-800-345-6007
14
Features and Controls
engine Stop / Throttle Control 
The engine stop / throttle control lever controls turn the 
engine off and controls the engine speed.  Move the throttle 
right to increase engine speed and left to decrease engine 
speed.  Moving the lever all the way to the left stops the 
engine.  Always operate at FULL throttle (lever fully right).  
Recoil Starter
The recoil starter is used to turn the engine over for starting.  
Fuel Shut-Off valve
The fuel shut-off valve is located below the air cleaner 
housing.  Always close the valve when the unit is not in use. 
Choke 
Close the choke for cold starting. Open the choke once the 
engine starts.  A warm engine may not require choking.  
Move the lever right to close the choke.
Fuel Tank
To remove the cap, turn counterclockwise.  
Chipper Cone / Shredder Hopper
Chipper Cone: The chipper cone is located on the front of 
the unit next to the engine.  Insert branches and tree limbs 
up to approximately 3” (7.6 cm) in diameter into the chipper 
cone.  NEVER insert hands past the mouth of the cone.
Shredder Hopper: The shredder hopper is on top of the 
unit.  Leaves and other light waste can be loaded into the 
shredder hopper.  NEVER insert hands into the hopper .
Debris Bag: Use the debris bag to collect the material 
discharged from the unit.  Do not operate the unit without 
the debris bag in place.
Control Functions
The information below briefly describes the function of individual controls.  Operating requires the combined use of several controls 
applied in specific sequences. To learn what combination and sequence of controls to use for various tasks see the OPERATION 
section.
Figure 1. Controls