Jacuzzi J - 480 Manual Do Utilizador

Página de 104
Page 76
J-400
14. Audio Communication Malfunction: Communication between the 
control panel and audio system is faulty. Shutdown power to the 
spa, wait 3 seconds and restart the spa to reset the communication. 
Contact your authorized dealer or service organization.
15. Blinking Heater icon: This icon will blink on and off to indicate that:
 
•  The temperature sensor is sensing a -20°F/6°C 
difference between the actual and set temperature or;
•  The temperature sensor is sensing a temperature above 
112°F/44°C or the hi-limit temperature sensor is sensing 
a temperature above 116°F/46°C.
16. Extended Temperature 
Activated:
 
The spa is set to go up to 
104°F (40°C), but it can 
be set to reach 106°F 
(41°C). To access the 
extended temperature you must press the “Up” (on the 
Quad Keypad) button and the button D at the same time for 2 
seconds. The system will now allow you to raise the temperature to 
106°F (41°C) and the LCD display will read 
“eXTenDeD 
teMPerature aCtivateD” (Figure A). To clear this message, 
just press the Down button on the Quad Keypad to lower the 
temperature below or back to 104°F (40°C).
17.  Please Check Filter!
 
This message will appear when the filter  
reminder time has expired (Figure B). 
Please remove the Proclear filters and 
filter bag for cleaning or replacement. 
18.  Feature not installed: (Exterior lights)
 
This message will appear when a 
user tries to activate the exterior 
lights and they are not installed 
(Figure C). To clear the message 
press button D to return to Main 
Menu.
106
F
Temp.
6:45 PM
Extended Temperature 
Activated
UP
C
B
A
D
Figure A
102
F
Temp.
6:45 PM
Please check filter!
Figure B
EXTERIOR
Feature not installed
C
B
A
D
Figure C