Page 78
J-400
17.0  Troubleshooting Procedures
In the unlikely event your spa is not working the way you believe it 
should, please first review all the installation and operating instructions in 
this manual and check the message on the panel display; second, if you 
are still not satisfied it is working properly, please follow the appropriate 
troubleshooting instructions.
ProbleM
PrOCeDure
NONE OF THE 
COMPONENTS 
OPERATE (i.e. 
pump light)
Check the control panel lights.
1.  If there are letters or symbols displayed on 
the screen, refer to the previous section to 
determine the meaning and action required.
2.  If nothing appears on the screen:
A. Check the household circuit breaker.
B. Contact you dealer or authorized service 
center.
PUMP DOES 
NOT OPERATE 
AND ICON DOES
Activate the “JETS”:
1.  If no sound is detected or if a “buzzing” sound 
is detected, turn off power to the spa and 
contact your dealer or service center.
2.  If motor operates but no water flows to jets:
A. Pump may not be properly primed. See 
instructions below.
B. Contact dealer or authorized service center.
Pump Priming Instructions:
1.  Turn off power to the spa.
2.  Remove the handle from the massage selector supplied by the pump 
you are priming.
3.  Loosen the massage selector’s cap slightly (counterclockwise), 
listening for the air to seep out.
4.  Tighten the cap finger-tight, replace the handle and turn the hot tub’s 
power back on.
note: This method must be used for the jet’s pumps because these 
pumps are not connected to the main filter system in any way.
CauTIOn: If freezing conditions exist and pump is not operational, 
take measures to protect the system from freeze damage. See 
Section titled “Winterizing” (page 70).