Nilfisk Alto 5 SB FA Manual Do Utilizador

Página de 48
19
1)
 Options / model variants
NEPTUNE 5 SB FA 
Indication 
on Display
Cause
Remedy
FLF
FLF
>
Flow sensor fault
Contact Nilfi sk-ALTO Service
Cold water operation possible
FLO
FLO
>
Water supply turned off or inadequate supply 
to machine
Required volume fl ow and pressure see 
chapter 9.4 Technical Data
>
Detergent tank empty
Fill detergent tank or set detergent me-
tering to „OFF“
>
Pressure regulation on the safety control 
block set to low water volume
Turn the twist grip on safety control block  
 
to higher water pressure/volume
>
Machine scaled
Contact Nilfi sk-ALTO Service
Fue 
Fue 
>
Fuel shortage
Fill fuel tank
Cold water operation possible
Hop
Hop
>
Motor overheated
Turn main switch in position „OFF“, let 
machine cool down
Remove extension cord, if being used.
Possible phase failure; have electrical 
connections checked
HOS
HOS
>
Machine overheated
Contact Nilfi sk-ALTO Service
LEA
LEA
>
Leakage or inadmissible operating condition 
by short-time operation
After three times of short-time ope ration 
the machine switches off. To reset: Turn 
main switch to position “OFF“, then start 
again. Keep trigger squeezed for longer 
than 3 seconds. If a leak occurs in the 
hose and gun and causes the machine 
to start and stop briefl y 3 times, then the 
machine will switch off.
>
Spray gun leaking
Repair Spray gun
>
High pressure hose, coupling or line system 
leaking
Replace high-pressure hose, retighten 
screw fi ttings
>
Detergent tank empty
Fill detergent tank or set detergent me-
tering to „OFF“
>
Water inlet fi lter dirty
Clean fi lter (see chapter 7.2.1)
>
High-pressure pump drawing in air
Repair leaks
LHE
LHE
>
Flame sensor sooted
Clean flame sensor (see chapter  
7.2.6).
>
Ignition or fuel system failure
Contact Nilfi sk-ALTO Service
Cold water operation possible
LHL
LHL
>
Burner failure
Contact Nilfi sk-ALTO Service
Cold water operation possible
POL 
POL 
>
Pump oil low
Fill to proper level (see chapter 7.2.3)
SEC
SEC
>
Temperature sensor damaged
Contact Nilfi sk-ALTO Service
Cold water operation possible
SEO
SEO
>
Temperature sensor damaged
Contact Nilfi sk-ALTO Service
Cold water operation possible
UPC
UPC
>
Microprocessor failure
Contact Nilfi sk-ALTO Service
8 Troubleshooting
8.1 
Indications on Display