 3
CHaNGING freqUeNCY SeTTING
NOTE: All fans leave the factory set to 
“1111”
You will only have to change the dip switch settings in the remote if you 
are using more than one fan in the same area and want to control them 
separately. 
DIP
SwITcheS
dIp SwITcheS 
Set to ‘1111’ 
(factory Setting)
dIp SwITcheS 
Set to ‘1001’
aUToMaTIC DeMoNSTraTIoN ProGraM
A multi-tone signal will verify the start of the test pro-
gram which proceeds as follows:
•  Lights slowly increase to full intensity.
•  Fan accelerates to speed three with audio tones.
•  Light dims to half intensity.
•  Fan accelerates to full speed with audio tones.
•  Fan reverses at full speed with audio tones.
•  Fan operates at full speed.
•  Fan turns off with audio tones (blades coast for a 
short time).
•  Lights turn off.
The complete cycle lasts slightly over one minute. It 
will continue to repeat until the 
 is turned off 
for more than five seconds, cancelling the program.
Programmed into every Inteli-Touch
®
 3 Series fan is 
an Automatic Demonstration Program. It can be used 
to fully demonstrate and test the operation of the fan.
to enter the demonstration program:
1. Turn 
 off for at least 5 seconds. This will 
clear the fan memory ready for programming.
2. Turn 
 on.
3. Immediately operate the buttons in the following 
sequence:
+
+
+
+
NOTE: DO NOT set dip switch setting in the remote 
to ‘0000’, this may cause frequency interference 
from other Casablanca Products. 
Step 1. Turn power OFF at the circuit breaker or fuse box and at the toggle 
switch, for the fan you want to change. 
Step 2. Remove the screws and switch plate from the existing switch box.
Step 3. Remove the screws holding the switch in the switch box.
Step 4. Pull the existing W-85 switch from the switch box to expose the dip 
switches located on the side of the control as shown in Figure #1.
Step 5. Change the dip switch settings, assuring that they are different from 
the previously installed  Inteli-Touch
®
 3 fan.
Step 6. Mount the W-85 Wall Control unit back into the wall electrical box.
Step 7. At the circuit breaker or fuse box and at the toggle switch, turn the 
power off for the fan whose frequency you are changing.
Step  8.  Within  20  seconds  of  restoring  power  to  the  ceiling  fan  and  the 
W-85 Wall Control press and hold both the “FAN” and “REVERSE” buttons 
as shown in Figure #2 for 3 seconds, you will hear one tone from the Piezo 
Buzzer indicating the command has been accepted.