Ryobi RYI2000T Manual Do Utilizador

Página de 64
9 — English
ELECTRICAL
Application/Equipment
Estimated 
Starting 
Watts*
Estimated 
Run 
Watts*
Emergency / Home Standby
Lights (qty. 4 x 75 W)
  300
300
Refrigerator
700
1350
46 in. Flat Panel Television
190
190
Satelite Receiver
250
250
Portable Fan
40
120
Heater
1300
1300
Laptop
250
250
Slow Cooker
270
270
Radio
  50
  50
Job Site
Electric Drill − 3/8 in.
600
1000
Quartz Halogen Work Light
1000
1000
Reciprocating Saw
960
1920 
Circular Saw − 7-1/4 in.
1400
2300
Miter Saw − 10 in.
1800
1800
Air Compressor − 1/4 HP
970
1600
Airless Sprayer − 1/3 HP
600
1200
*Wattages listed are approximate. Check tool or appliance for actual wattage.
POWER MANAGEMENT
To prolong the life of the generator and attached devices, 
it is important to take care when adding electrical loads to 
the generator. There should be nothing connected to the 
generator outlets before starting its engine. The correct and 
safe way to manage generator power is to sequentially add 
loads as follows:
1.  With nothing connected to the generator, start the engine 
as described later in this manual.
2.  Plug in and turn on the first load, preferably the largest 
load you have.
3. Permit the generator output to stabilize (engine runs 
smoothly and attached device operates properly).
4.  Plug in and turn on the next load.
5.  Again, permit the generator to stabilize.
6.  Repeat steps 4 and 5 for each additional load.
Never add more loads than the generator capacity. Take 
special care to consider surge loads in generator capacity 
as previously described.
CAUTION:  
Do not overload the generator’s capacity. Exceeding the 
generator’s wattage/amperage capacity can damage the 
generator and/or electrical devices connected to it.
FEATURES
PRODUCT SPECIFICATIONS
ENGINE
Engine Type ......................... Single Overhead Cam (SOHC)
Bore x Stroke ............................................. 88 mm x 64 mm
Cooling System ...................................................Forced Air
Compression Ratio ...................................................... 8.5:1
Starting System ......................................................... Recoil
Ignition System ............................................................ T.C.I.
Spark Plug ................................................NHSP LD A7RTC
Engine Lubricant Volume......................................... 0.42 qt.
Fuel Volume ..............................................................1.0 gal.
GENERATOR
Rated Voltage .........................................120 V AC/12 V DC
Rated Amps ..........................................13.33A AC/7.5A DC
Rated Running Watts ............................................. 1,600 W
Starting Watts ......................................................... 2,000 W
Rated Frequency ........................................................ 60 Hz