York P2LBX16F14501 Manual Do Utilizador
12
TABLE A-2: DIRECT DRIVE BLOWER SET-UP
BLOWER SET-UP
COOLING CAPACITY
0.20 in. w.c.
0.50 in. w.c.
FURNACE
OUTPUT
BTU/Hr.
BLOWER
MOTOR
HP
Speed Speed
Htg. CFM
Range
1
Tons
2
MOTOR
HP
Clg. CFM
Range
60,000
Low
Med-Low
615 - 790
78,000
Med-Low
Med-High
799 - 1027
P3DHX12F08001
90,000
GT10 DD
1/2
Med-High
High
922 - 1185
3
1/2
690 - 1200
91,000
Med-Low
Med-High
932 - 1199
101,000 Med-Low
Med-High
1035
-
1330
117,000 Med-High
High
1198
-
1540
P2DHX16F12001
128,000
GT12-10 DD
1/2
Med-High High 1311
-
1685
4 1/2
1000
-
1600
130,000 High
High
1332
-
1712
P2LBX16F14501
143,000
G10 DD
1/2
High High
1465
-
1883
4 1/2
1065
-
1600
(1)
Heating Range values based on temperature rise. Upper values may exceed measured airflow values in Table A-3.
(2)
Nominal values only.
TABLE A-3: BELT DRIVE BLOWER SET-UP
Blower Set-Up
Cooling Capacity
0.20 in. w.c.
0.50 in. w.c.
Pulley Belt Pulley Belt
Furnace
Model
Blower Motor
Motor Blower
Motor Blower
Tons CFM
Range
3½ x
⅝
7 x ¾
4L430
3½ x
⅝
7 x ¾
4L430
P4LBX20F19001 G12 3/4
HP
3½ x
⅝
7 x ¾
4L430
3½ x
⅝
7 x ¾
4L430
4 1300
-
1535