TABLE A-2: DIRECT DRIVE BLOWER SET-UP 
BLOWER SET-UP 
COOLING CAPACITY 
0.20 in. w.c. 
0.50 in. w.c. 
FURNACE 
OUTPUT 
BTU/Hr. 
BLOWER 
MOTOR 
HP
 
Speed Speed 
Htg. CFM 
Range 
1
 
Tons 
2
 
MOTOR 
HP
 
Clg. CFM 
Range
 
60,000 
Low 
Med-Low 
615 - 790 
78,000 
Med-Low 
Med-High 
799 - 1027 
P3DHX12F08001 
90,000 
GT10 DD 
1/2 
Med-High 
High 
922 - 1185 
1/2 
690 - 1200 
91,000 
Med-Low 
Med-High 
932 - 1199 
101,000 Med-Low 
Med-High 
1035 
1330 
117,000 Med-High 
High 
1198 
1540 
P2DHX16F12001 
128,000 
GT12-10 DD 
1/2 
Med-High High 1311 
1685 
4 1/2 
1000 
1600 
130,000 High 
High 
1332 
1712 
P2LBX16F14501 
143,000 
G10 DD 
1/2 
High High 
1465 
1883 
4 1/2 
1065 
1600 
(1)
 Heating Range values based on temperature rise. Upper values may exceed measured airflow values in Table A-3.      
 
(2)
 Nominal values only. 
 
 
 
 
TABLE A-3: BELT DRIVE BLOWER SET-UP 
Blower Set-Up 
Cooling Capacity 
0.20 in. w.c. 
0.50 in. w.c. 
Pulley Belt Pulley Belt 
Furnace 
Model 
Blower Motor 
Motor Blower 
 
Motor Blower 
 
Tons CFM 
Range 
3½ x 
 
7 x ¾ 
4L430 
3½ x 
 
7 x ¾ 
4L430 
P4LBX20F19001 G12  3/4 
HP 
3½ x 
 
7 x ¾ 
4L430 
3½ x 
 
7 x ¾ 
4L430 
4 1300 