MIDI Functions
N-100
 
Owner’s Manual
ENGLISH
23
MIDI Functions
These operations let you make detailed adjustments to MIDI settings.
MIDI Transmit/Receive Channel 
Selection
In any MIDI control setup, the MIDI channels of the transmitting and 
receiving devices must be matched for proper data transfer. 
This parameter enables you to specify the channel on which the N-100 
transmits or receives MIDI data. 
Setting the Transmit Channel
While holding down the 
[DEMO]
 and 
[PIANO/VOICE]
 buttons, press one of the 
C1–E2 keys.
Setting the Receive Channel
While holding down the 
[DEMO]
 and 
[PIANO/VOICE]
 buttons, press one of the 
C4–F5 keys.
Local Control ON/OFF
“Local Control” refers to the fact that, normally, the N-100 keyboard controls its internal tone gen-
erator, allowing the internal voices to be played directly from the keyboard. This situation is “Local 
Control On,” since the internal tone generator is controlled locally by its own keyboard. 
Local control can be turned OFF, however, so that the N-100 keyboard does not play the internal 
voices, but the appropriate MIDI information is still transmitted via the MIDI OUT terminal when 
notes are played on the keyboard. At the same time, the internal tone generator responds to MIDI 
information received via the MIDI IN terminal.
While holding down the 
[DEMO]
 and 
[PIANO/VOICE]
 buttons, press the C6 
key. Pressing the C6 key repeatedly toggles between Local Control On and Off.
In Dual, Voice 1 data is transmit-
ted on its specified channel and 
Voice 2 data is transmitted on the 
next greater channel number rela-
tive to the specified channel. In 
this case, no data is transmitted if 
the transmit channel is set to 
“OFF.”
ALL:
“Multi-timbre” Receive. This 
allows simultaneous reception of 
different parts on all 16 MIDI 
channels, enabling the N-100 to 
play multi-channel song data 
received from a music computer 
or sequencer.
1+2:
“1+2” Receive. This allows simul-
taneous reception on channels 1 
and 2 only, enabling the N-100 to 
play 1 and 2 channel song data 
received from a music computer 
or sequencer.
Program change and other like 
channel messages received will 
not affect the N-100’s panel set-
tings or the notes you play on the 
keyboard.
Data for the demo song and 50 
piano preset songs cannot be 
transmitted via MIDI.
NOTE
11
14 16
9
5 6 8 10 12 13 15 OFF
3
1
7
4
2
11
14 16
9
5 6 8 10 12 13 15 1+2 ALL
3
1
7
4
2
Transmit Channel
(C1–E2)
Receive Channel
(C4–F5)
E2
F5
C4
C1
C0
Default setting: ON
C6
C7