Yamaha PM5D-RH V2 Manual Do Utilizador

Página de 409
PM5D/PM5D-RH V2 / DSP5D Owner’s Manual    
Operating section
161
19
Other functions
Adjusting the faders and input/output gain (Calibration)
Depending on the conditions of use, discrepancies may occur in the behavior of the motor faders. you can use the Calibration 
function to correct such discrepancies. If necessary, you can also make fine adjustments to the analog input/output gain.
1
While holding down the [ENTER] key of the 
panel, turn on the power of the PW800W 
power supply.
After the opening screen, the following calibration 
menu screen will appear.
2
Click one of the following buttons to choose 
what you want to calibrate.
A window for the calibration item you selected will 
appear.
3
Make calibration settings as directed by the 
instructions that appear in the window.
4
Click the OK button in the window.
The calibration settings will be applied, and the PM5D 
will start up in normal mode.
Here you can execute a semi-automatic procedure for cali-
brating the faders of the specified channel strip (INPUT, 
DCA, STEREO A/B, ST IN/FX RTN). This window will 
also appear if a problem with the fader settings is detected 
when the PM5D is started up.
1
Click a fader select button to add a check mark 
to the faders you want to calibrate.
If problems with certain faders were detected during 
start-up, those buttons will be on (green), and check 
marks will already be shown for them.
2
Click the START CALIBRATION button; calibra-
tion will begin automatically.
A progress bar will indicate the state of the process.
3
The automatic processing will end when the 
progress bar reaches 60%. Manually move all 
faders you specified for calibration to the posi-
tions listed below in the following order:
1
   –
2
   –20 dB
3
   0 dB
4
   +10 dB
4
After you have set the faders to the correct 
position, press the [ENTER] key.
Processing will proceed to the next fader position.
5
Repeat steps 3–4 for each fader position 
1
4
.
6
Verify that calibration has been completed and 
that all fader select buttons are now off. Then 
click the OK button.
The calibration settings will be stored in internal mem-
ory. If a fader select button remains on (green), 
calibration has failed. Try executing calibration once 
again.
Note
The progress bar will indicate “Writing...” while the settings are 
being written to internal memory; do not turn off the power 
while this indication is visible.
CALIBRATE FADER 
POSITION
The FADER CALIBRATION win-
dow will appear, allowing you to 
calibrate the specified faders.
CALIBRATE AD INPUT 
GAIN (make fine adjust-
ments to the analog 
input gain; PM5D-RH 
model only)
The AD INPUT TRIM window 
will appear, allowing you to 
make fine adjustments to the 
gain of the specified analog 
input port.
CALIBRATE OUTPUT 
GAIN (make fine adjust-
ments to the output 
ports)
The OUTPUT TRIM window will 
appear, allowing you to make 
fine adjustments to the gain of 
the specified output port.
Calibrating the faders