MGP16X/MGP12X     Owner’s Manual
10
Rack Mounting
The unit requires at least 11U* of rack space. To take into 
account the cable connections, we recommend to ensure at least 
13U* of rack space.
* 11U corresponds to about 489mm and 13U is about 578mm.
 Precautions for Rack Mounting
This unit is rated for operation at ambient temperatures ranging 
from 0 to 40 degrees Celsius. If you install this unit along with 
other devices in a poorly ventilated rack, the ambient temperature 
inside the rack may rise, resulting in inefficient performance.
Be sure to rack-mount in the following conditions so the unit does 
not overheat.
• When mounting the unit in a rack with devices such as power 
amplifiers that generate a significant amount of heat, leave 
more than 1U of space between the MGP and other equipment. 
Also either leave the open spaces uncovered or install appropri-
ate ventilating panels to minimize the possibility of heat 
buildup.
• To ensure sufficient airflow, leave the rear of the rack open and 
position it at least 10 centimeters from walls or other surfaces. 
If the rear of the rack cannot be left open, install a commer-
cially available fan or similar ventilating option to secure suffi-
cient airflow. If you’ve installed a fan kit, there may be cases in 
which closing the rear of the rack will produce a greater cool-
ing effect. Refer to the rack and/or fan unit manual for details.
 Mounting the MGP16X/MGP12X
1.
Two metal rack-mount brackets are screwed 
onto the unit. Use a screwdriver to remove 
these brackets.
2.
Turn the brackets over, and fasten them into 
place again using the same screws.
Fasten them to the mixer in order (as shown): q center, 
w front, and e back.
CAUTION
Be sure to use the same screws that were removed in step 
1. Using other screws can cause damage.
 MGP16X
3.
Mount the unit into the rack, and fasten it into 
place.
w
q
e
w
q
e
11U
13U