TROUBLESHOOTING GUIDE - Observe Safety Guidelines detailed in the beginning of this manual.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
CAUTION
TROUBLESHOOTING AND REPAIR
F-8
F-8
POWERARC® 5500
OUTPUT  PROBLEMS
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENTS(S)
RECOMMENDED
COURSE OF ACTION
Low  weld  output  and  low  auxiliary
output.
1.  Perform the 
2.  If the rotor voltage is low, the field
capacitor (C1) or bridge (D1) may
be faulty.  Test or replace.
3.  Check the rheostat (R1).  Normal
resistance is 3.3 ohm.  
4.  The rotor may be faulty.  Per form
5.  The  engine  RPM  may  be  low.
Perform  the 
6.  If  engine  idle  RPM  is  okay,  the
engine may have lost horsepow-
er and be in need of major repair.  
1.  The  generator  brushes  may  be
worn.  See the Maintenance sec-
tion  of  this  manual  or  contact
your 
local 
Lincoln 
Electric
Authorized Field Service Facility.  
2.  The  engine  RPM  may  be  low.