POWERARC® 5500
OUTPUT PROBLEMS
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENTS(S)
RECOMMENDED
COURSE OF ACTION
Low weld output and low auxiliary
output.
output.
1. Perform the
2. If the rotor voltage is low, the field
capacitor (C1) or bridge (D1) may
be faulty. Test or replace.
be faulty. Test or replace.
3. Check the rheostat (R1). Normal
resistance is 3.3 ohm.
4. The rotor may be faulty. Per form
5. The engine RPM may be low.
Perform the
6. If engine idle RPM is okay, the
engine may have lost horsepow-
er and be in need of major repair.
er and be in need of major repair.
1. The generator brushes may be
worn. See the Maintenance sec-
tion of this manual or contact
your
tion of this manual or contact
your
local
Lincoln
Electric
Authorized Field Service Facility.
2. The engine RPM may be low.