RANGER 250
Onan P216
(K1725-1)
Kohler CH20
(K1725-2)
2 cylinder
16 HP @
3600 RPM
(Onan)
20 HP @
3600 RPM
(Kohler)
High Idle 3700
Full Load 3500
Low Idle 2400
44 (714) - Onan
38 (624) - Kohler
Bore x Stroke inch
(mm)
3.25 x 2.625 
(83 x 67) (Onan)
3.03 x 2.64
(77 x 67) (Kohler)
12 VDC Battery &
Starter
(Group 58; 435 cold
crank amps)
Battery Charger
20 A. regulated (K1725-1)
15 A. regulated (K1725-2)
(Push Button Start)
Fuel: 12 gal.
45.4 L
Oil: 1.8 Qts.
1.7 L (Onan)
Oil: 2.0 Qts.
1.9 L (Kohler)
Cooling System:
Air-Cooled
TECHNICAL SPECIFICATIONS - RANGER 250 (K1725-1/K1725-2)
INPUT - GASOLINE ENGINE
Make/Model
Description
Speed (RPM)
Displacement
Starting
Capacities
cu. in. (cu. cm.)
System
RATED OUTPUT - WELDER
Welding Output
Volts at Rated Amps
Duty Cycle Max.
OCV @ 3700 RPM
CC STICK & PIPE DC Output
25 Volts at 250 Amps
100%
STICK / PIPE Output Range
20 to 250 Amps
TIG Output Range
20 to 250 Amps
80 Volts
CV WIRE DC Output
25 Volts at 250 Amps
100%
CV WIRE Output Range
14 to 28 Volts
OUTPUT - GENERATOR
Auxiliary Power
1
8,000 Watts, 60 Hz
120/240 Volts
100% Duty Cycle
PHYSICAL DIMENSIONS
Height
Width
Depth
Weight
30.00* in.
21.50 in.
42.25 in.
452 lbs. (205 kg.) K1725-1
762.0 mm
546.0 mm
1073.0 mm
434 lbs. (197 kg.) K1725-2
* Top of enclosure, add 6.0” (152 mm) for exhaust
ENGINE COMPONENTS
Lubrication
Valve Lifters
Fuel System
Governor
Full Pressure
Solid (Onan)
Vacuum Pulse Pump (Onan)
Mechanical Governor
with Full Flow Filter
Hydraulic (Kohler)
Mechanical Fuel Pump (Kohler)
5% Regulation
Air Cleaner
Engine Idler
Muffler
Engine Protection
Duel Element
Automatic Idler
Low noise muffler: Top outlet
Shutdown on low oil
can be rotated.  Made from
pressure.
long life, aluminized steel.
Receptacles
Auxiliary Power Circuit Breaker
Other Circuit Breakers
Two 120 VAC Duplex
Two 20 Amp for Two Duplex 
25 Amp for Battery Charging
(5-20R)
Receptacle
Circuit
One 120/240 VAC Dual
Two 35 Amp for Dual Voltage
150 Amp for 42 Volt Wire Feeder
Voltage
Power
Full KVA (14-50R)
1.  Output rating in watts is equivalent to volt-amperes at unity power factor.  Output voltage is within ± 10% at all loads up to rated capacity.  When welding,
available auxiliary power will be reduced.