3.  Tool Offset (L system) 
3.4  Tool Life Management I 
 
 
 
I-99 
Refer to "3 (II). Tool Offset (M system)" for M system.
3.4.1  Tool Life Management Method  
 
By setting the service lifetime (or service life count) to "0" for each tool, the following four tool life 
management methods can be selected.  
Life management method 
Service lifetime 
setting 
Service life count 
setting 
1. Time only 
 
Set to "0". 
2. Count only 
Set to "0". 
 
3. Time and count 
 
 
4. No management 
Set to "0". 
Set to "0". 
 
(1)  Tool life management by time 
The cutting time (G01, G02, G33, etc.) after a tool selection (T) command is carried out is incremented 
to the usage time corresponding to the commanded tool.  
If the usage time reaches the service lifetime when a tool selection command is executed, a warning is 
output to the user PLC.  
When the usage time reaches the service lifetime, the corresponding tool No. (#) on the TOOL LIFE 
DATA screen is highlighted.  
 
(2)  Tool life management by count 
The count for the commanded tool is incremented when the first cutting feed starts after a tool selection 
(T) command is carried out. If no cutting feed is executed after the selection of a tool, the count is not 
incremented.  
If the count equals the service life count for the commanded tool when a tool selection command is 
executed, a warning is output to the user PLC.  
When the count exceeds the service life count (when the cutting feed starts after a tool selection 
command), the corresponding tool No. (#) on the TOOL LIFE DATA screen is highlighted.  
 
(3)  Tool life management by time and count 
The tool life is managed simultaneously by time and count. 
If the usage time reaches the service lifetime, or the count equals the service life count for the 
commanded tool when a tool selection command is executed, a warning is output to the user PLC.  
When the usage time reaches the service lifetime, or when the count exceeds the service life count, the 
corresponding tool No. (#) on the TOOL LIFE DATA screen is highlighted.  
 
(4) No management 
The usage time and count are incremented, but no warning is output to the user PLC, and the tool No. 
(#) on the TOOL LIFE DATA screen is not highlighted.  
 
 
3.4.2  Conditions for Counting (incrementing) 
 
The usage time (or count) is incremented when a cutting feed (G1, G2, G3, G33) is executed. Note that they 
are not incremented in the following conditions: 
• When the base specification parameter "#1103 T-Life" is OFF. 
• During machine lock 
• During miscellaneous function lock (input signal from the PLC) 
• During dry run 
• During single block operation 
• When the count ON signal of the data used is OFF. (Input signal from the PLC)