Mitsubishi Electronics 60/60S Manual Do Utilizador

Página de 559
3.  Tool Offset (M system) 
3.1  Tool Offset 
 
 
 
I-116 
Refer to "3 (I). Tool Offset (L system)" for L system.
3.1.4  Manual Tool Length Measurement 
 
 
By moving a tool manually from the reference to measurement point, the travel distance from the basic to 
measurement point can be measured and set as tool offset.   
 
 
(1)  Tool length measurement I 
 
 
When the tool is placed in the machine coordinate zero point, the distance from the tool tip to 
measurement point (workpiece top end) can be measured and set as tool offset data. 
 
When TLM basic length (#1102 tlm) = 0 
and SURFACE #0 = 0 are set, tool length 
measurement I mode is set.
 
 
Machine coordinate zero point
 
Workpiece
 
Table
 
Manual travel distance 
(tool length offset data)
 
 
 
 
 
(2)  Tool length measurement II 
 
 
When the tool is placed in the machine coordinate zero point, the distance from the reference point to 
tool tip can be measured and set as tool offset data. 
 
 
 
 
Manual travel distance
 
Machine coordinate zero point
 
Gauge block 
SURFACE #0={{ 
Tool offset data 
(internal calculation value) 
T
LM
 basic length 
Table