5.  Stored Stroke Limit 
5.2  Stored stroke limit II 
 
 
 
III-31 
5.2  Stored stroke limit II 
 
The boundary is set with the parameters (axis parameters
 
#8204 OT-CHECK-N
,
 #8205
 
OT-CHECK-P
) or with the 
program commands. Either the inside or the outside of the set boundary is the prohibited range. Whether the 
inside or outside of the range is prohibited is determined by parameter (
#8210 OT-INSIDE
). When the inside is 
selected, this function is called stored stroke limit IIB. 
When using program commands, entry of the tool into the prohibited range is prohibited with G22, and entry 
into the prohibited range is enabled with G23. 
The stored stroke limit II function can be invalidated for each axis with the parameter setting (
#8202 OT-CHECK 
OFF: 1
). 
 
"
#8210 OT-INSIDE
" can be set for each axis, but when used in combination, the following type of operation is 
possible. 
 
 
X Z 
Movement 
prohibited 
range 
 
 
 
 
 
 
Moveable range 
 
Outsid
Outsid
 
 
 
 
Moveable range 
 
 
 
 
Outsid
Inside 
 
Moveable range 
 
 
 
 
 
 
 
Inside 
Inside 
 
Moveable range