8.  Maintenance Functions 
8.1  Data Input/Output Function 
 
 
 
III-58
 
8.1.1  Data Format 
 
 
The tape output format of single data is as follows: 
 
 
E
O
B
"Ox ... " indicates hexadecimal data. 
Example : Ox64 = (6 
∗ 16 + 4 = 100)
O : Type of output data 
N : Sequence number (0,1,2 ... in units of four L data items) 
L : Data is output in units of 4 bytes (hex). 
M: Data is output in units of 1 byte (hex). 
0 x 3 2 0 0 5 0 
 
0 x 6 4 
 
0 x 0 
 
0 x 3 2 
 
0 x 1 0 0 0 1 
N 0 L 3 2 0 0 5 0 L 6 4 L 0 L 3 2
N 1 L 1 0 0 0 1
Feed 
Feed
Header 
Data
Data
Feed 
Feed 
E
O
B
E
O
B
 
 
 
The output format of continuous data (batch output data) is as follows: 
 
Feed 
Feed 
Header 1 
Data 1
Data n
Feed
E
O
B
E
O
B
E
O
B
Feed
Header 2
Data 2 
Feed
Header n
Feed 
E
O
B
E
O
B
E
O
R
 
 
(Note)  The number of feeds is the value set with the input/output parameter #9114.