SPARC JPS1 Implementation Supplement: Fujitsu SPARC64 V • Release 1.0, 1 July 2002
Raw (unmarked) uncorrectable error (multibit error)
Marked uncorrectable error
Correctable Error on Extended UPA Data Bus
When the SPARC64 V processor detects a correctable error in the extended UPA 
incoming data, the processor corrects the data and uses it. The restrainable error 
ASI_AFSR.CE_INCOMED
 is indicated.
When the processor detects a correctable error in the outgoing data to the extended 
UPA data bus before the data transfer occurs, it corrects the error and sends the 
corrected data to the extended UPA data bus. If the correctable error is also detected 
in the data in the U2 cache, the processor corrects the source data in the U2 cache, 
too. The error is not reported to software.
Uncorrectable Error in Incoming Data from Extended UPA 
Data Bus 
At the time data is received, the SPARC64 V processor handles 
UE
s in data coming 
from the extended UPA data bus, as follows:
Marked 
UE
 in incoming data from the extended UPA data bus.
 When the 
processor detects a marked 
UE
 in such data, the processor transfers that data to 
the destination register or cache without modification. The error is not reported to 
software when the marked 
UE
 is received at the extended UPA data bus interface. 
Raw 
UE
 in incoming data from the extended UPA data bus. 
When the processor 
detects a raw 
UE
 in such data, the processor applies error marking to that data. 
The processor changes the data to marked 
UE
 with 
ERROR_MARK_ID
= 0, 
indicating a memory system error, and then transfers the marked 
UE
 data to the 
destination register or cache. 
If the error marking is applied to incoming cacheable data, the restrainable error 
ASI_AFSR.UE_RAW_L2$FILL
 is indicated. If the error marking is applied to incoming 
noncacheable data, the error is not reported to software at the time of error 
marking.
Note – 
The destination register or cache always receives the marked 
UE
 data for 
both marked 
UE
 and raw 
UE
 in the data sent via the extended UPA data bus, as 
described above.
Finally, the treatment of an uncorrectable error (
UE
) coming from the extended UPA 
bus depends on whether the access was to cacheable or noncacheable data and 
whether the access was an instruction fetch, load, or store instruction, as follows: