DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-65
ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line) 
10
ANL-LINE (8-Port Analog Line),
ANL-NE-L (8-Port Neon Analog Line)
The 8-Port Analog Line circuit packs are:
These circuit packs provide eight ports for single line on-premises or 
off-premises analog endpoints such as analog voice terminals, queue warning 
level lamps, recorded announcements, dictation machines, PagePac
 paging 
equipment, external alerting devices, modems, facsimile machines, and AUDIX 
voice ports. The TN769 supports a neon message waiting lamp. The other 
eight-port analog lines do not support the lamp.
Test #48 may cause some terminal equipment to ring briefly during daily 
maintenance. If this ringing is disturbing the customer or the terminal equipment, 
it should be disabled using the Tests field of the station administration screen. 
However, on some releases of the software, this action disables Tests #6, #47, 
and #35 as well as Test #48. Test #47 may cause a false alarm when the port is 
connected to off-premises equipment, some non-voice terminal equipment, and 
some loop equipment. If this is the case, then the test should be disabled using 
the Tests field of the 
change station <extension>
 command.
No maintenance of the terminal connected to the 8-Port Analog Line circuit pack 
or 8-Port Neon Analog Line circuit pack is performed, except to determine 
whether or not the terminal is connected. Failures of the neon message waiting 
lamp power (for ANL-NE-L only) and the common ringing application circuitry are 
1.
Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier 
designation (for example, A, B, C, D, or E); SS is the address of the slot in the carrier 
where the circuit pack is located (for example, 01, 02, ..., etc.); and pp is the 2-digit 
port number (for example, 01).
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to 
Run
1
Full Name of MO
ANL-LINE
MIN
test port PCSSpp l
8-Port Analog Line
ANL-LINE
WRN
test port PCSSpp sh
8-Port Analog Line
ANL-NE-L
MIN
test port PCSSpp l
8-Port Neon Analog Line
ANL-NE-L
WRN
test port PCSSpp sh
8-Port Neon Analog Line
TN742
TN431 [G3iV2-386]
TN769
TN443 [G3iV2-386]
TN712
TN467 [G3iV2-386]
TN411 [G3iV2-386]