DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-66
ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line) 
10
reported as part of the Common Port Circuit Pack errors (see errors 1281 and 
1793 in the XXX-BD (Common Port Circuit Pack) Maintenance documentation).
Hardware Error Log Entries and Test to Clear 
Values
Notes:
a. These are in-line errors and can only be resolved over time.
40960
indicates that too many simultaneous incoming ringing 
attempts were made on this board. Only four ports on a board may 
be ringing simultaneously. A fifth incoming call will cause an inline 
error from the board.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
2.
Major or Minor alarms on this MO may be downgraded to Warning alarms based on the values used 
in the 
set options
 command.
Table 10-26.
8-Port Analog Line Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port PCSSpp sh r 1
1 (a)
40960 
40975 
40977
None
15 (b)
Any
Audits and Updates 
Test (#36)
18
0
busyout station 
<extension>
WRN
OFF
release station <extension>
130(c)
None
WRN
ON
test port PCSSpp sh
257 (d)
Station Present Test 
(#48)
WRN
OFF
test port PCSSpp sh r 3
513
Battery Feed Test 
(#35)
MIN/ 
WRN
2
ON
test port PCSSpp sh r 2
769 (e)
Loop Around and 
Conference Test(#47)
test port PCSSpp l r 3
1025
NPE Crosstalk Test 
(#6)
MIN/WR
N
2
ON
test port PCSSpp l r 3
1281 (f)
1793 (f)