Routine Maintenance Procedures
Page 5-22
Software Upgrade
5
NOTE:
The
The
save translation
command cannot function if the translation corruption
message appears.
Disable TTI
Enter
change system-parameters features
and press
Enter.
Use Page 2 of the
form to disable Terminal Translation Initialization (TTI) by changing the value to
n
.
List Configuration Software Version
Issue the
list configuration software-versions
command to determine if any
patches have been applied.
NOTE:
If the system must be restored to the old software, download the correct
patches.
If the system must be restored to the old software, download the correct
patches.
Disable Scheduled Maintenance
Enter
change system-parameters maintenance
, and press
Enter
. Use this form
to prevent scheduled daily maintenance from interfering with the update or
upgrade.
upgrade.
NOTE:
If scheduled maintenance has begun, set the value of the “Stop Time” field
to 1 minute after the current time. If scheduled maintenance has not yet
begun, change the value of the “Start Time” field to a time after the upgrade
is finished.
If scheduled maintenance has begun, set the value of the “Stop Time” field
to 1 minute after the current time. If scheduled maintenance has not yet
begun, change the value of the “Start Time” field to a time after the upgrade
is finished.
Disable Alarm Origination to INADS
1. Enter
change system-parameters maintenance
and press
Enter
.
2. Enter
n
in the
Alarm Origination
field and press
Enter
.
3. For some releases of system software, disable
Cleared Alarm Notification
and
Restart Notification
before submitting the form.
!
CAUTION:
Disabling alarm origination prevents the system from generating
alarms, thus preventing unnecessary trouble tickets.
alarms, thus preventing unnecessary trouble tickets.
Save Announcements
1. If the system is equipped with a TN750/B Announcement circuit pack,
enter
display announcements
, and press
Enter
. If administered recorded
announcements are listed, enter
save announcements
[from PCSS] and