DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Routine Maintenance Procedures 
Page 5-22
Software Upgrade 
5
NOTE:
The 
save translation
 command cannot function if the translation corruption 
message appears.
Disable TTI
Enter 
change system-parameters features
 and press 
Enter.
 Use Page 2 of the 
form to disable Terminal Translation Initialization (TTI) by changing the value to 
n
.
List Configuration Software Version
Issue the 
list configuration software-versions
 command to determine if any 
patches have been applied.
NOTE:
If the system must be restored to the old software, download the correct 
patches.
Disable Scheduled Maintenance
Enter 
change system-parameters maintenance
, and press 
Enter
. Use this form 
to prevent scheduled daily maintenance from interfering with the update or 
upgrade.
NOTE:
If scheduled maintenance has begun, set the value of the “Stop Time” field 
to 1 minute after the current time. If scheduled maintenance has not yet 
begun, change the value of the “Start Time” field to a time after the upgrade 
is finished.
Disable Alarm Origination to INADS
1. Enter 
change system-parameters maintenance 
and press 
Enter
2. Enter 
n
 in the 
Alarm Origination 
field and press 
Enter
3. For some releases of system software, disable 
Cleared Alarm Notification
 
and 
Restart Notification
 before submitting the form.
!
CAUTION:
Disabling alarm origination prevents the system from generating 
alarms, thus preventing unnecessary trouble tickets. 
Save Announcements
1. If the system is equipped with a TN750/B Announcement circuit pack, 
enter 
display announcements
, and press 
Enter
. If administered recorded 
announcements are listed, enter 
save announcements 
[from PCSS] and