Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-245
CARD-MEM (Memory Card) 
10
5. Once the alarm is resolved, enter the 
save translation
 command to store 
the current system translations to the memory card.
6. If applicable, enter the 
save announcements
 command to store the 
current announcements to the memory card.
Error Log Entries and Test to Clear Values
1.
Run the Short Test sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
Table 10-74.
Mrmory Card Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test card-mem
1(a)
Memory Card Insertion 
Test (#695)
MINOR
OFF
test card-mem
257(b)
Memory Card Format and 
Read Test (#696)
MINOR
OFF
test card-mem
513(c)
Any
Memory Card Match and 
Read Test (#697)
WARNING
OFF
test card-mem
769(d)
Memory Card 
Write-Protected Test 
(#698)
WARNING
OFF
test card-mem
1025(e)
104 
105 
106 
107 
108
Memory Card Dir. 
Recovery Test (#699)
MINOR
OFF
test card-mem
1281(f)
Any
Memory Card Translation 
Data Integrity Test (#694)
MINOR
OFF
test card-mem long
1537(g)
104 
105 
106 
107 
108
Memory Card 
Erase/Write/Read Test 
(#693)
MINOR
OFF
test card-mem long
3329(h)
any
None
MINOR/ 
MAJOR
OFF
3841(i)
Any
Save Translation
MINOR
OFF
save translation
3843(j)
Any
Save Translation
MINOR
OFF
save translation
Continued on next page