Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-415
DAT-LINE (Data Line) 
10
Error Log Entries and Test to Clear Value
s
Notes:
a. This is a software audit error that does not indicate any hardware 
malfunction. Run the Short Test Sequence and investigate errors (if any).
b. This error type indicates that the circuit pack has been removed or has 
been insane for more than 11 minutes. To clear the error, reinsert or 
replace the circuit pack.
c. This error is logged when the Data Line circuit pack finds an error with the 
transmit/receive circuitry of an administered Data Line on circuit pack 
insertion. Perform the following procedure:
1. Issue the 
busyout board PCSS
 command to busyout the Data Line 
circuit pack on which this port resides.
2. Issue the 
reset board PCSS
 command. Check the Hardware Error 
Log to determine if Error Type 769 is logged again for the DAT-LINE 
MO.
NOTE:
When displaying errors, set the Active Alarms Only field to "n."
If Error Type 769 reappears, replace the DAT-LINE circuit pack. If 
Error Type 769 does not reappear, proceed to Step 3.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate 
test description and follow the recommended procedures.
Table 10-114.
Data Line Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port PCSSpp sh r 1
1
Digital Loop Around 
Test (#171)
MINOR
ON
test port PCSSpp sh r 2
15(a)
Any
Audit Update Test 
(#36)
18
0
busyout port PCSSpp
WARNING
OFF
release port PCSSpp
130 (b)
None
WARNING
ON
test port PCSSpp sh
257
Conference Circuit 
Test (#7)
MINOR
ON
test port PCSSpp l r 2
513
NPE Crosstalk Test 
(#6)
MINOR
ON
test port PCSSpp l r 2
769(a)
Any (c)
None