DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-416
DAT-LINE (Data Line) 
10
3. Issue the 
release board PCSS
 command to release the Data Line 
circuit pack on which this port resides.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when 
inspecting errors in the system. By clearing error codes associated with the 
Digital Loop Around Test,
 for example, you may also clear errors generated from 
other tests in the testing sequence.
NPE Crosstalk Test (#6)
The NPE Crosstalk Test verifies that this port’s NPE channel talks on the selected 
time slot and never crosses over to time slots reserved for other connections. If 
the NPE is not working correctly, one-way and noisy connections may be 
observed. This test is usually part of a port’s Long Test Sequence and takes 
about 20 to 30 seconds to complete.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
Digital Loop Around Test (#171)
X
X
ND
NPE Crosstalk Test (#6)
X
ND
Conference Circuit Test (#7)
X
ND
Audit Update Test (#36)
X
X
ND
Table 10-115.
TEST #6 NPE Crosstalk Test 
Error 
Code
Test 
Result
Description/Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000
ABORT
System resources required to run this test are not available. The port may 
be in use on a valid call. Use 
status data-module
 to determine when the 
port is available for testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page