DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-453
DID-TRK (DID Trunk) 
10
Loop Around and Conference Circuit Test (#33)
This test checks the reflective and non-reflective loop around and conference 
capabilities of a DID port circuit. The test that uses 404-Hz, 1004-Hz, and 
2804-Hz tones is an on-board test only. Each tone is separately transmitted to 
and from the port (loop around within the port) and verified.
This test may fail due to noise induced by adjacent electric power lines. 
Customers having this problem should resolve it with their local power company. 
To temporarily alleviate the alarm caused by the failure of this test, the test may 
be disabled from trunk administration Test field. (This also disables the port 
diagnostic test.
0
NO 
BOARD
The test could not relate the internal ID to the port (no 
board).
1. Check to ensure that the board translations are 
correct. Translate the board, if necessary.
2. Issue the 
busyout board
 command.
3. Issue the 
reset board
 command.
4. Issue the 
release busy board
 command.
5. Issue the 
test board
 command. This should 
re-establish the linkage between the internal ID and 
the port.