Lucent Technologies R5SI Manual Do Utilizador
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-523
DIOD-TRK (DIOD Trunk) [G1.2SE]
10
Loop Around and Conference Circuit Test (#33)
This test checks the reflective loop and conference abilities of a CO port circuit.
The test uses 404 Hz, 1004 Hz, and 2804 Hz tones. Each tone is transmitted
separately through the loop and checked.
The test uses 404 Hz, 1004 Hz, and 2804 Hz tones. Each tone is transmitted
separately through the loop and checked.
1004
ABORT
The port was seized by a valid call during the test. The
test has been aborted. Use the
test has been aborted. Use the
display port PCSSpp
command to determine the trunk group/member number
of the port. Use the
of the port. Use the
status trunk
command to determine
the service state of the port. If the service state indicates
that the port is in use, then the port is unavailable for
certain tests. (Refer to the "Status Commands" section in
Chapter 10, "Maintenance Commands and
Trouble-Clearing Aids" for a full description of all
possible states.) You must wait until the port is idle
before retesting.
that the port is in use, then the port is unavailable for
certain tests. (Refer to the "Status Commands" section in
Chapter 10, "Maintenance Commands and
Trouble-Clearing Aids" for a full description of all
possible states.) You must wait until the port is idle
before retesting.
2000
ABORT
Response to the test request was not received within the
allowable time period.
allowable time period.
2100
ABORT
Could not allocate the necessary system resources to
run this test.
run this test.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
Any
FAIL
The NPE of the tested port was found to be transmitting
in error. This causes noisy and unreliable connections.
in error. This causes noisy and unreliable connections.
1. Replace the circuit pack.
PASS
The port is correctly using its allocated time slots.
User-reported troubles on this port should be
investigated by using other port tests and by examining
trunk or external wiring.
User-reported troubles on this port should be
investigated by using other port tests and by examining
trunk or external wiring.
Table 10-141.
TEST #6 NPE Crosstalk Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page