Lucent Technologies R5SI Manual Do Utilizador
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-639
EMG-XFER
10
NOTE:
These tests only show up in the test sequence if there is a TN768
Tone-Clock Board in the port network being tested.
Tone-Clock Board in the port network being tested.
Emergency Transfer Query Test (#124)
This test queries the hardware for the state of the Emergency Transfer switch (or
switches in a High or Critical Reliability system) and reports the result. If the
switch(es) is (are) in a position where the system software can control
Emergency Transfer, then the test passes. If the switch(es) is (are) in a position
where the system software cannot control Emergency Transfer, then the test fails.
In the PPN, the Maintenance/Tape Processor controls Emergency Transfer and,
in the EPN, the EPN Maintenance circuit pack controls Emergency Transfer. The
system software does not have control of Emergency Transfer within a cabinet if
the switch(es) is (are) in the manual ON or manual OFF state for that cabinet.
switches in a High or Critical Reliability system) and reports the result. If the
switch(es) is (are) in a position where the system software can control
Emergency Transfer, then the test passes. If the switch(es) is (are) in a position
where the system software cannot control Emergency Transfer, then the test fails.
In the PPN, the Maintenance/Tape Processor controls Emergency Transfer and,
in the EPN, the EPN Maintenance circuit pack controls Emergency Transfer. The
system software does not have control of Emergency Transfer within a cabinet if
the switch(es) is (are) in the manual ON or manual OFF state for that cabinet.
Table 10-185.
TEST #124 Emergency Transfer Query Test
Error
Code
Code
Test
Result
Description/Recommendation
1000
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2000
ABORT
Response to the test request was not received within the allowable time
period.
period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to ABORT with error code 2000, check for system
powering problems with the A carrier (PPN or EPN). Resolve all
DC-POWER alarms. Then, repeat the test.
DC-POWER alarms. Then, repeat the test.
3. If the test continues to ABORT with a 2000 error code, check for and
resolve all DUPINT (Duplication Interface) errors in a PPN for a high or
critical reliability system, or MAINT (EPN Maintenance circuit pack)
errors in an EPN. Repeat the test.
critical reliability system, or MAINT (EPN Maintenance circuit pack)
errors in an EPN. Repeat the test.
2029
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1
FAIL
Emergency Transfer is manually turned OFF via the Emergency Transfer
switch(es).
switch(es).
2
FAIL
Emergency Transfer is manually turned ON via the Emergency Transfer
switch(es).
switch(es).
1. Place the switch (or switches in a PPN for a High or Critical Reliability
system) in the AUTO position.
Continued on next page