Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Routine Maintenance Procedures 
Page 5-65
Troubleshooting Multimedia Call Handling (MMCH) 
5
Conference x Endpoint y Vid form under the Capability section. In this section, a 
“y” or “c” suggests that the endpoint has video. An “e” means ept has not 
declared any video capability in cap set, “n” is audio only, and “blank” means 
audio add-on. 
Also check page 1 of the Status Conference x Endpoint y Vs form for indication of 
the video state for the endpoint values.
Calls Terminate Correctly but Are Unstable
Description
A number of conditions will lead to some or all endpoints having stability 
problems during the course of a conference. A lack of stability from an endpoint 
is noticeable by a lack of a video switching while the party is the only talker or 
excessive disconnects from that endpoint.
Synchronization
Generally, the most common problem is a mismatch in synchronization sources 
between the endpoint and the DEFINITY MMCH. This typically causes low-level 
(Px64) handshake problems that can trigger the endpoint/MMCH to disconnect 
the call. The MCCH’s timers are set to sufficiently high values so that, normally, 
the endpoint will timeout and disconnect first. If installed in a customer network, it 
is a good idea to perform an audit of the path synchronization is being supplied. 
If there are different clock sources between endpoints and the DEFINITY MMCH, 
some problems are sure to occur. The severity of these problems can range from 
a handshake failure every few seconds to one per day. Depending on the type of 
endpoint, this can cause the endpoint to disconnect or just freeze video until the 
main problem is resolved.
Specifically, PictureTel System 4000 endpoints seem to be the most sensitive to 
instability. The Lucent Technologies Vistium also disconnects fairly infrequently. 
Last, the CLI Rembrandt II VP freezes video and waits for framing to be 
recovered.
Network Configuration Concerns with 
Synchronization
When auditing a network for synchronization, avoid unnecessary hops. Thus, a 
switch providing star-configuration synchronization is preferred over a 
daisy-chain configuration. Additionally, if there are DEFINITY PBXs that have 
EPNs, synchronization should be provided to sub nodes from the same port 
network through which the PBX receives its synchronization. Passing 
synchronization through the PBX Expansion Interface adds an unnecessary hop 
to the path and creates another potential point of failure.