Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-855
MAINT (EPN Maintenance Circuit Pack) 
10
and written to. EPN Maintenance circuit pack maintenance utilizes the DPR on 
the Network Control circuit pack for placing messages that eventually get 
passed along to the Expansion Interface circuit pack in the EPN cabinet and 
subsequently to the EPN Maintenance circuit pack in the EPN cabinet.
Sanity Handshake Test (#106)
This test checks the EPN Maintenance circuit pack’s ability to respond to 
queries. A message is sent to the EPN Maintenance circuit pack which then 
sends a message back. If the response message is received, then the EPN 
Maintenance circuit pack is queried for the EPN cabinet type. The EPN 
Maintenance circuit pack reads pins on the backplane of carrier A that identify 
the type of cabinet and report this information. If a valid cabinet type is returned, 
then the test passes.
Table 10-240.
TEST #104 Network Control Circuit Pack Dual Port Ram (DPR) Test 
Error 
Code
Test 
Result
Description/Recommendation 
1000
ABORT
System resources required for this test are not available.
1030
ABORT
Internal system error
2028
ABORT
Internal system error
2029
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
10401
ABORT
Test disabled using a software patch.
FAIL
The test failed.
1. Since a portion of the Network Control circuit pack (the Dual Port Ram) 
is actually being tested here, run the Short Test Sequence against the 
Network Control circuit pack (SW-CTL) and follow the maintenance 
procedures for Test #325.
2000
FAIL
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS
The communication to the EPN Maintenance circuit pack is good at least 
up to the Network Control circuit pack. If there are still problems 
communicating with the EPN Maintenance circuit pack, then these 
problems must be with either the EXP-LINK (Expansion Links), EXP-INTF 
(Expansion Interface) circuit pack, or the EPN MAINT (Maintenance) circuit 
pack.
Continued on next page