Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-857
MAINT (EPN Maintenance Circuit Pack) 
10
MGR I Channel Local Loop Around Test (#228)
This test is destructive.
This test checks the on-board circuitry of the EPN Maintenance circuit pack 
associated with the serial link for the terminal connection. This test does not 
cause the terminal to become disconnected. However, any data being displayed 
FAIL
 
(cont’d.)
2. If the -5 volt unit is good and this test continuously fails, background 
maintenance automatically escalates to an EPN Maintenance circuit 
pack Reset (Test #306). Otherwise, you can manually invoke an EPN 
Maintenance circuit pack Reset by issuing the 
test maintenance long
 
command and evaluating any generated error codes from Test #306. If 
Test #306 passes, this test should also PASS. Otherwise, use the 
following steps to determine if the EPN Maintenance circuit pack, or the 
serial link to the EPN Maintenance circuit pack, is defective:
Duplicated Expansion Links:
1. Determine which serial link is the standby by issuing the 
status system
 system technician command.
2. Switch Expansion Links by entering 
set expansion-link 
PCSS
 where PCSS is the 4-character Expansion Interface 
circuit pack location for the Standby link.
3. Run the Short Test Sequence against the EPN Maintenance 
circuit pack. If Test #106 still fails, replace the EPN 
Maintenance circuit pack and retest. Otherwise, follow the 
error routines for any errors that are logged by this Short Test.
Single Expansion Interface Link Switch:
1. Replace the EPN Maintenance circuit pack and invoke the 
Short Test Sequence.
2. If error persists, replace the EPN Expansion Interface circuit 
pack, 
at a time when the EPN can go down with minimal 
inconvenience
.
3. If the error still persists, the problem is with the actual serial 
link in A carrier backplane and not with the EPN Maintenance 
circuit pack.
PASS
The communications path to and from the EPN Maintenance circuit pack is 
sane, and the EPN Maintenance circuit pack can read and report the 
correct EPN cabinet type. The EPN Maintenance circuit pack may still have 
problems related to Tests #228, #229, #303, or #306.
Table 10-241.
TEST #106 Sanity Handshake Test  — 
Continued
Error 
Code
Test 
Result
Description/Recommendation 
Continued on next page