Page 10-933
MMI-BD 
10
TSI Crosstalk Test (#6)
This test is non-destructive.
The Time Slot Interchanger (TSI) chip controls connectivity to the TDM bus. The 
TSI Cross Talk Test verifies that this TSI talks on the selected TDM bus time slot 
and never crosses over to time slots reserved for other connections. If the TSI is 
not working correctly, one-way and noisy connections may occur. If the test 
passes, then the TSI is able to communicate over the TDM bus. This test is part of 
the circuit pack’s demand and scheduled long test sequence, and takes 
approximately 20 to 30 seconds to complete.
1.
D = Destructive, ND = Non-destructive
2.
Refer to the repair procedure described in XXX-BD (Common Port Circuit Pack) for a description 
of this test.
Table 10-265.
System Technician-Demanded Tests: MMI-BD
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
Reset Board 
Sequence
D/ND
1
TSI Crosstalk (#6)
X
ND
TSI Looparound Test (#1108)
X
ND
MMI SYNC Status Test (#1123)
X
ND
MMI SYNC Status Test (#1122)
X
ND
Control Channel Looparound Test (#52)
2
X
X
ND
SAKI Sanity Test (#53)
X
D
Continued on next page
Table 10-266.
TEST #6 TSI Crosstalk Test
Error 
Code
Test 
Result
Description/Recommendation
ABORT
Internal system error. This is an abnormal abort.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1002
ABORT
The system could not allocate time slots for the test, the traffic load on the 
system is very high, or the time slots are out-of-service due to TDM-BUS errors. 
Refer to “TDM-BUS” to diagnose any active TDM Bus errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic, 
repeat the test at 1-minute intervals a maximum of 5 times.
Continued on next page