Lucent Technologies R5SI Manual Do Utilizador

Página de 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-961
M/T-ANL (Maintenance/Test Analog Port) 
10
Analog Port Sanity Test (#963)
This test verifies that the port circuitry involved in the analog trunk testing on the 
Maintenance/Test Analog Port is functioning properly.
This test will abort if an ATMS Test Call is in progress on the Maintenance/Test 
Analog Port when the test is requested.
Table 10-277.
TEST #963 Analog Port Sanity Test 
Error 
Code
Test 
Result
Description/ Recommendation
2000
ABORT
Response to the test request was not received within 
the allowable time period.
2100
ABORT
System resources required to run this test are not 
available.
2500
ABORT
An internal operation failed; the test could not be 
completed.
1. Retry the command at 1 minute intervals a 
maximum of 3 times.
2. If the test continues to fail, escalate the problem.
50
FAIL
The switch was unable to communicate with the port 
circuitry used for analog trunk testing.
1. Reset the circuit pack via the 
busyout board 
PCSS
reset board PCSS
release board PCSS
 
command sequence.
2. Test the port again via the 
test port PCSS01 l
 
command.
3. If the test fails again, replace the circuit pack.
PASS
The Maintenance/Test Analog Port analog trunk 
testing capability is operating correctly.
Continued on next page