Maintenance Object Repair Procedures
Page 10-961
M/T-ANL (Maintenance/Test Analog Port)
10
Analog Port Sanity Test (#963)
This test verifies that the port circuitry involved in the analog trunk testing on the
Maintenance/Test Analog Port is functioning properly.
Maintenance/Test Analog Port is functioning properly.
This test will abort if an ATMS Test Call is in progress on the Maintenance/Test
Analog Port when the test is requested.
Analog Port when the test is requested.
Table 10-277.
TEST #963 Analog Port Sanity Test
Error
Code
Test
Result
Description/ Recommendation
2000
ABORT
Response to the test request was not received within
the allowable time period.
the allowable time period.
2100
ABORT
System resources required to run this test are not
available.
available.
2500
ABORT
An internal operation failed; the test could not be
completed.
completed.
1. Retry the command at 1 minute intervals a
maximum of 3 times.
2. If the test continues to fail, escalate the problem.
50
FAIL
The switch was unable to communicate with the port
circuitry used for analog trunk testing.
circuitry used for analog trunk testing.
1. Reset the circuit pack via the
busyout board
PCSS
,
reset board PCSS
,
release board PCSS
command sequence.
2. Test the port again via the
test port PCSS01 l
command.
3. If the test fails again, replace the circuit pack.
PASS
The Maintenance/Test Analog Port analog trunk
testing capability is operating correctly.
testing capability is operating correctly.
Continued on next page